CAPS & ADAPTORS


SHOWING ITEMS 49 - 60 OF 84 RESULTS
view_module view_list
$ 115.79
418TM-40
Capping pipe in extractor valve assemblies, storage tanks, and monitoring wells. The 418 is easy to installl and remove, because of the top ears configuration. Ribbing on the side allows easy hand tightening.

• Top mounted ears allow easy removal and installation
• Rugged construction for long life
• Durable and non-corrosive
• Liquid tight seal
• UL#E79903
• CSA#LR50370-10 approved
$ 51.54
$ 74.42
61SALP-1020-EVR
Pressure decay testing of underground storage tank systems has identified the joint between the tight-fill adapter and the nipple or tank riser as a persistent leak point. Considerable movement takes place along the hose while the fill elbow is connected. Walk-downs and changes from one compartment to another move the hose across the pavement, rotating the elbow along with it. The result can be a loosening of the adapter. As the adapter backs off, the seal between it and the nipple is relaxed and a leak path is created allowing vapors to escape to the atmosphere. Vacuum-assist dispensing systems can aggravate this situation due to the slight pressurization of the UST. The 61SA Swivel adapter mates with 4" top-seal delivery elbows and features a top section that rotates with hose movement while the bottom section remains securely in place maintaining seal integrity.

• Dual Seals – Ensures a vapor- and liquid-tight seal.
• Conductive, Self-Lubricating Retaining Rod – Ensures maintenance-free, reliable service life.
• Same Internal Dimension as Standard 633T Adaptors – To minimize pressure drop and maximize flow rates for quick product delivery.
• 61SALP-MA - EVR Approved for use with E85
$ 290.46
61VSA-1020-EVR
Stage I Vapor Recovery adapters are installed in spill containment manholes on the vapor recovery riser pipe from an underground gasoline storage tank. They mate with the vapor recovery elbow on the delivery transport truck when recovery of gasoline vapors is required. The OPW 61VSA Vapor Swivel adapter is a poppeted adapter, designed to mate with a vapor recovery elbow, featuring a top section that rotates with hose movement while the bottom section remains securely sealed to the 4-inch tank riser.

• Dual Seals – ensure a vapor and liquid-tight seal.
• Conductive, Self-Lubricating Retaining Rod – ensures maintenance-free, reliable service life.
• Same Internal Dimension as Standard 633T Adaptors – to minimize pressure drop and maximize flow rates for quick product delivery.
• Self Guiding Poppet – for consistent tight seal.
$ 404.03
62M-0375
Monitoring Probe Caps are installed on tank riser pipes to help prevent vapors from escaping or water from entering the tank. Monitoring Probe Caps include a wire grommet fitting to accommodate the electronic tank gauge probe. The 62M Monitoring Probe & ADAPTER Kit includes a 4" side-sealing ADAPTER, 4" side-sealing cap (tapped), and a 3/8" or 1/2" wire grommet to secure the cable from an electronic tank gauge probe in the tank riser pipe. A bracket, located on the underside of the cap, is provided to install a tension wire to relieve strain on probe cables. The 62M is gasketed to seal against water and debris entering, or vapors from escaping the tank. The cap includes provisions for a padlock to secure entry.
$ 91.54
62M-0500
Monitoring Probe Caps are installed on tank riser pipes to help prevent vapors from escaping or water from entering the tank. Monitoring Probe Caps include a wire grommet fitting to accommodate the electronic tank gauge probe. The 62M Monitoring Probe & ADAPTER Kit includes a 4" side-sealing ADAPTER, 4" side-sealing cap (tapped), and a 3/8" or 1/2" wire grommet to secure the cable from an electronic tank gauge probe in the tank riser pipe. A bracket, located on the underside of the cap, is provided to install a tension wire to relieve strain on probe cables. The 62M is gasketed to seal against water and debris entering, or vapors from escaping the tank. The cap includes provisions for a padlock to secure entry.
$ 100.60
62PMC-0400
The OPW 62PMC is designed to thread or solvent-weld to a 61SPVC 4" slotted PVC monitoring well pipe. The 62PMC is constructed of durable PVC with a stainless steel hinge pin for resistance to rust and corrosion. An API warning statement, "Monitoring Wellâ?¦Do Not Fill," is permanently molded into the cap. The 62PMC can be locked with a long-shank padlock.
$ 38.49
633LC-1000
OPW 633LC Lock Clamp is designed to lock the OPW adapter onto the riser pipe, preventing any potential vapor leaks from pressurized systems. The locking clamp slips over the riser pipe. The 633T, 633TE, or 1611 adapter is then threaded onto the riser pipe. Next the lock clamp should be slid up the riser until the protrusions in the lock clamp line up with the notches in the adapter. Once the adapter and clamp are engaged, the lock clamp can be tightened and the adapter will be locked onto the riser pipe, preventing it from being loosened by a delivery elbow. Additionally, the lock clamp can be turned upside down on the riser pipe to lock the riser into the base of all OPW spill containers, which have notches in them similar to the adapters. Using the lock clamp in this manner will lock the riser pipe into the spill containe
$ 48.05
633T-8075
OPW 633T Top-Seal adapters thread onto the fill pipe of underground storage tanks, and are designed to mate with top-seal delivery elbows. Use OPW 634TT, 634TE or 634TTP Top-Seal Caps with 633T adapters. Tight-Fill Top-Seal adapters are installed in spill containment manholes on the fill riser pipe from an underground fuel storage tank. They mate with the gravity drop delivery elbow on the transport truck.
$ 54.15
633T-8076
OPW 633T Top-Seal adapters thread onto the fill pipe of underground storage tanks, and are designed to mate with top-seal delivery elbows. Use OPW 634TT, 634TE or 634TTP Top-Seal Caps with 633T adapters. Tight-Fill Top-Seal adapters are installed in spill containment manholes on the fill riser pipe from an underground fuel storage tank. They mate with the gravity drop delivery elbow on the transport truck.
$ 74.26
633TC-8090
Tight-Fill Top-Seal adapters are installed in spill containment manholes on the fill riser pipe from an underground fuel storage tank. They mate with the gravity drop delivery elbow on the transport truck. OPW coaxial vapor recovery fittings provide an easy, inexpensive means to convert existing conventional 4" underground storage tank fill pipes to coaxial vapor recovery installations when Stage I Vapor Recovery is required. Normally, little or no digging or breaking of concrete is necessary. Simply remove existing tight-fill adapter and drop tube (if installation is so equipped), and insert an OPW 61TC Coaxial Drop Tube and the 633TC adapter. The OPW 633TC adapter is designed to mate with a coaxial delivery elbow.