ABOVE GROUND


SHOWING ITEMS 25 - 36 OF 65 RESULTS
view_module view_list
14603
  • Cast iron construction
  • Full range of sizes
  • Double tapped full FPT thread
  • Rugged design with solid hexes for secure wrench grip
  • Can be used as reducing bushing for continuous piping
$ 33.96
14605
  • Cast iron construction
  • Full range of sizes
  • Double tapped full FPT thread
  • Rugged design with solid hexes for secure wrench grip
  • Can be used as reducing bushing for continuous piping
$ 33.96
$ 7.52
184---2200 MB
Double tapped bushings are used to reduce tank or pipe opening thread size.

• Male NPT threads (OD)
• Female NPT threads from the top down and from the bottom up
• Pipe plugs are solid cast iron with male threads
$ 36.17
184---2400 MB
Double tapped bushings are used to reduce tank or pipe opening thread size.

• Male NPT threads (OD)
• Female NPT threads from the top down and from the bottom up
• Pipe plugs are solid cast iron with male threads
$ 31.24
184---2500 MB
Double tapped bushings are used to reduce tank or pipe opening thread size.

• Male NPT threads (OD)
• Female NPT threads from the top down and from the bottom up
• Pipe plugs are solid cast iron with male threads
$ 23.80
199ASV-2075
The OPW 199ASV Anti-Siphon Valve is designed to help prevent siphoning of an aboveground storage tank should a leak or break occur in the fuel supply line. The 199ASV installs on the top of an aboveground storage tank with a suction rod on the inlet and the fuel supply line (to a remote pump) on the outlet of the valve. A poppet in the valve remains normally closed, isolating the tank from siphoning. When the remote pump is activated, it overcomes a factory-adjusted spring set to a predetermined hydrostatic head pressure and allows flow of fuel out of the AST. An internal pressure relief valve helps absorb thermal expansion in the fuel supply line. The 199ASV is available in female NPT threads with four different factory-adjusted hydrostatic head pressure settings.

• Factory-Adjusted Hydrostatic Head Pressure Settings - Allow for quick, safe and easy installation on above ground tanks
• Internal Pressure Relief Valve - Helps protect piping & fittings from damage due to thermal expansion. Set to operate between 20 to 40 PSI (1.3 to 2.7 bar)
• Aluminum Bodies - Compatible with gasoline, diesel, kerosene, ethanol, methanol, fuel oil, and jet fuels
$ 335.25
202-0660
The OPW 202 Emergency Vent is designed to prevent an aboveground storage tank from becoming over-pressurized by providing full-bore, high-capacity venting in the event of a fire or blockage of the OPW 23, 113, 523V, or 623V. The 202 is a vapor-tight, spring-loaded emergency vent. When the AST builds pressure to 2.5 psi, the spring-loaded lid opens full-bore and discharges vapors upward to relieve the pressure. The lid remains open for inspection to indicate a problem with the normal tank venting, or if a fire has taken place, until manually reset. The appropriate 202 Series vent is determined by the emergency venting capacity requirements of the AST and the type of connection at the tank's emergency vent opening. The OPW 202 Emergency Vent is available in 4", 6", and 8" openings with female NPT connections.

Alerts Tank Operators of Possible Venting Problems – When the emergency vent is actuated, the lid remains open for inspection until manually reset. The actuation of the emergency vent indicates abnormal excessive pressure build-up in the tank due to either a blockage in the normal tank vent or in the event of a rapid expansion of vapors possibly from a fire.
$ 289.76
$ 14.62
$ 45.24
244O--0100 AV
Emergency vents are installed on aboveground storage tanks as a code requirement. Emergency vents provide high capacity pressure relief if the tank is exposed to fire. When the internal tank pressure reaches the opening pressure of the vent, the weighted cover moves up on the center pin allowing air to escape. When the internal tank pressure falls, the cover automatically lowers back onto the body and is automatically reset.

The 244 emergency vent is for "emergency pressure relief only" and must be used in conjunction with a "normal vent" or pressure vacuum vent. The 244 emergency vent must be properly sized and selected for each specific tank application in order to meet the proper "venting capacity" requirements.
$ 109.15
244O--0200 AV
Emergency vents are installed on aboveground storage tanks as a code requirement. Emergency vents provide high capacity pressure relief if the tank is exposed to fire. When the internal tank pressure reaches the opening pressure of the vent, the weighted cover moves up on the center pin allowing air to escape. When the internal tank pressure falls, the cover automatically lowers back onto the body and is automatically reset.

The 244 emergency vent is for "emergency pressure relief only" and must be used in conjunction with a "normal vent" or pressure vacuum vent. The 244 emergency vent must be properly sized and selected for each specific tank application in order to meet the proper "venting capacity" requirements.
$ 159.09